1. This function corresponds to the following IBM RPQ options:
4214: OPT 19=1
3268: SC9506
3287: SC3739
2. Available only in non-SCS operation.
EXAMPLE: %Y32,1%
will set the printer to accept FF anywhere it occurs.
FUNCTION 33: AUTOMATIC FUNCTION AT END OF JOB
This function implements and IBM RPQ and will have effect as soon as it is received.
SYNTAX: %Y33,<n1>%
OPTION DESCRIPTION
*0 NL will automatically be executed after the print
buffer is completed (unless an FF, NL, or CR was
last in the buffer)
1 FF will automatically be executed after the print
buffer is completed (unless a Form Feed was last
in the buffer)
RELATED: Y31, FF Valid at End of Print Buffer
NOTES:
1. This function corresponds to the following IBM RPQ options:
4214: OPT 20=2
3268: SC9507
3287: SC3740
2. Available only in non-SCS operation.
3. Settings different from factory default are not recommended
EXAMPLE: %Y33,1%
will set the printer to issue a Form Feed automatically at the end of the print buffer.
FUNCTION 34: LAST LF ON PAGE SENT AS FF
This function helps you maintain Top-of-Form setting for each print job by automatically appending a
FormFeed at the end of each job.
SYNTAX: %Y34,<n1>%
OPTION DESCRIPTION
n1
*0 Do not add FF at end of page
1 Count lines in FSL 5 and send FF at end of job
EXAMPLE: %Y34,1%
will add a FF at end of each job.
FUNCTION 35: FORM FEED USAGE
32
yes