Dascom 2600 User Guide Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Drukarki Dascom 2600 User Guide. Dascom 2600 User Guide User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 2

Tally Dascom 2610 IX TRADEMARK ACKNOWLEDGEMENTS “IBM” is a trademark of International Business Machines Corporation. “EPSON” is a trademark of Eps

Strona 3

Tally Dascom 2610 87 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ * * * * <ESC>[4m Underline ON √ * * * * <ESC>

Strona 4

Tally Dascom 2610 88 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ <ESC>[g<n1> <n2><2> Set grap

Strona 5

Tally Dascom 2610 89 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ * * * * <ESC>[<n> v Set vertical tab √ √

Strona 6

Tally Dascom 2610 90 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ √ √ √ <ESC><SO> Double-wide printing ON

Strona 7

Tally Dascom 2610 91 7.2.1 PJL commands These PJL commands can be used with internal Ethernet interface as well as with externa

Strona 8

Tally Dascom 2610 92 7.2.3 List of available MTPL barcodes Type Barcode Type Barcode A* 2/5 Matrix (default) N UPC A (with HRI) B* 2/5 Industr

Strona 9

Tally Dascom 2610 93 7.2.5 Royal Mail Customer barcode The Royal Mail Customer barcode is a special Mail type barcode. It is printed in characte

Strona 10 - Tally Dascom 2610

Tally Dascom 2610 94 printer has the possibility of scaling standard size characters up to factor 99 by means of control sequences (LC

Strona 11 - TABLE OF CONTENTS

Tally Dascom 2610 95 7.2.9 List of additional control Codes You can use both the ESC sequences and the control codes Sequences Control codes

Strona 12

Tally Dascom 2610 96 7.3 Interfaces Specifications Your matrix printer offers connectivity via a parallel interface, USB and Ethernet interfa

Strona 13

Tally Dascom 2610 1 TABLE OF CONTENTS 1 Printer at a glance ...

Strona 14 - 1 Printer at a glance

Tally Dascom 2610 97 7.3.1 Parallel I/O IEEE 1284 The bidirectional parallel interface offers the “nibble” mode of IEEE1284 interface. This enab

Strona 15 -  Rear View

Tally Dascom 2610 98 7.3.2 Ethernet I/O 10/100 Mulitprotocol The Ethernet interface enables the printer to connect to local area networks. Its a

Strona 16 -  For Cut Sheets

Tally Dascom 2610 99 Example of a Printer connected to a computer in an Network ◆ The assumed address space corresponds to the TCP/IP address, cl

Strona 17 - 1.4 Parts description

Tally Dascom 2610 100 7.3.4 Optional Serial Interface RS232C Your printer’s serial interface supports the RS232C specification. The signals a

Strona 18 - 2 Installation

Tally Dascom 2610 101 1) The serial cable length must not exceed 15 meters. 2) Make sure the “Interface Setup” selects serial interface

Strona 19

Tally Dascom 2610 102 Interface cable (serial interface) The cables used must be shielded. The cable shield must be connected to the connector shie

Strona 20

Tally Dascom 2610 103 Protocols ◆ Memory mode XON/XOFF The received characters are stored in a FIFO buffer (first in/first out). The characters a

Strona 21

Tally Dascom 2610 104 ◆ ENQ/STX protocol In addition to this XON/XOFF message, the possibility exists of requesting a status byte from the printe

Strona 22

Tally Dascom 2610 105 8 Options and accessories The following options can be ordered for your printer. 8.1 Options Tractor Unit 2600 T

Strona 23 - 3 Installing the paper

Tally Dascom 2610 106 8.2 Consumables Ribbons Name Part no. Ribbon cassette monochrome black for narrow model 99061 Ribbon cassette monochrom

Strona 24

Tally Dascom 2610 2 6.1.5 Network Interface Status ...

Strona 25

Tally Dascom 2610 107 9 General Specifications 9.1 Printer Specifications Print System Mono-chrome serial impact dot matrix Print Technolo

Strona 26

Tally Dascom 2610 108 Tab Speed 50 ips Graphic Densities Horizontal: 60 / 72 / 80 / 90 / 120 / 180 / 240 / 360 DPI (dot per inch) Vertical:

Strona 27

Tally Dascom 2610 109 Paper Handling Feeding method: Friction (Single) and Tractor (FF-front / FF-rear / FF-pull) Path selection: By select

Strona 28

Tally Dascom 2610 110 Power Supply Unit type: Autosensing wide range power supply Power cord: Detachable Voltage rating: AC 100 to 240V / 47Hz t

Strona 29

Tally Dascom 2610 111 9.2 Non-Scalable Fonts, Code Pages and National Character Sets ID for ESC R/ESC ( High Speed Draft Draft Roman Sans Se

Strona 30

Tally Dascom 2610 112 ID for ESC R/ESC ( High Speed Draft Draft Roman Sans Serif Courier (incl. Courier IBM) OCR-B OCR-A Prestige Script Orator Go

Strona 31

Tally Dascom 2610 113 9.3 Paper Specifications 9.3.1 Standard Tractor (Front, Rear and Pull position) – narrow and wide versions

Strona 32

Tally Dascom 2610 114 9.3.2 Front Feed / Manual Insertion – Narrow and wide versions Usable figures of print area (dimensions in mm (inches))

Strona 33

Tally Dascom 2610 115 10 Maintenance Your printer requires very little care. Occasional cleaning and replacement of the ribbon cartridge are al

Strona 34

Tally Dascom 2610 116 10.2 Troubleshooting Your printer is extremely reliable, but occasionally problems may occur. This chapter provides inf

Strona 35

Tally Dascom 2610 3 9.3.1 Standard Tractor (Front, Rear and Pull position) – narrow and wide versions ... 113 9.3.2 Front Fee

Strona 36

Tally Dascom 2610 117 10.2.2 Paper Handling Problems and Solutions Problem Solution Paper cannot be loaded or fed. • Make sure that the pap

Strona 37

Tally Dascom 2610 118 The printer is on but it will not print. • Make sure that the Online indicator is lit. • If you use the interface cable,

Strona 38

Tally Dascom 2610 FCC STATEMENT Changes or modifications not expressly approved by the responsible for compliance could void the user’s authority

Strona 39

Tally Dascom 2610 DASCOM REPRESENTATIVES GERMANY DASCOM Europe GmbH Heuweg 3 D-89079 Ulm Deutschland Tel.: +49 (0) 731 2075 0 Fax: +49 (0) 731 2075

Strona 40

Tally Dascom 2610 1 1 Printer at a glance 1.1 Unpacking the printer Besides this manual, the package will contain: a power cord, a ribbon cartr

Strona 41

Tally Dascom 2610 2 1.3 Prepare your printer  Front View  Rear View

Strona 42

Tally Dascom 2610 3  For Fanfold  For Cut Sheets

Strona 43

Tally Dascom 2610 4 1.4 Parts description 1 Control Panel LED: The 2-line LED with 4 keys panel indicates the operating status and allows simple

Strona 44

Tally Dascom 2610 5 2 Installation 2.1 Placing the printer Place the printer on a solid, flat, stable surface such that the printer

Strona 45

Tally Dascom 2610 6 2.2.1 Parallel interface (IEEE 1284) Make sure that the printer and the computer are switched off and connect the parallel c

Strona 46

Tally Dascom 2610 I Important Safety Instructions (English) Read the following instructions thoroughly before starting up your printer.  Never

Strona 47 - 5.3 Menu structure

Tally Dascom 2610 7 2.2.4 Serial Interface (RS-232C) as option 2.2.5 Connecting the power Plug in the power cord to the printer power

Strona 48

Tally Dascom 2610 8 2.3 Installing the ribbon cartridge 1) Switch off the power. 2) Unfold the top cover and follow the steps 1.2.3.4 in the be

Strona 49

Tally Dascom 2610 9 4) Insert the ribbon cartridge till it is tightly locked in position. 5) Insert the ribbon fabric in between the print hea

Strona 50

Tally Dascom 2610 10 3 Installing the paper The printer can handle either single sheets or continuous forms. The printer is able to print up

Strona 51

Tally Dascom 2610 11 3.2 Paper path introduction 3.2.1 Cut sheet paper handling (front friction only) 1) Place the paper path lever to th

Strona 52

Tally Dascom 2610 12 3.2.2 Fanfold paper handling 3.2.2.1 Front push tractors for fanfold 1) Close the front cover if previously opened.

Strona 53

Tally Dascom 2610 13 5) If you do not need to adjust the left margin go to the next step. Open the right and left tractor flaps, insert fanfold p

Strona 54

Tally Dascom 2610 14 3.2.2.2 Rear tractors for fanfold

Strona 55

Tally Dascom 2610 15 3.2.2.3 Top pull tractors for fanfold For the steps ② and ③, please refer to the 2.3

Strona 56

Tally Dascom 2610 16 3.2.3 Top-Of-Form adjustment For pull tractor (PullTr), follow the steps below to adjust the first print position: 1) Remo

Strona 57

Tally Dascom 2610 II Wichtige Sicherheitshinweise (German) Lesen Sie bitte diese Sicherheitshinweise durch, bevor sie den Drucker in Betrieb nehmen

Strona 58

Tally Dascom 2610 17 4 Control Panel Operation General functions for the keys are clearly designated on the Panel label. Some other special

Strona 59 - 5.5 Display messages

Tally Dascom 2610 18 ◆ Keys 1)【Online】 a) Every press on this switch toggles the status between Online and Offline. When the printer is Online, it

Strona 60

Tally Dascom 2610 19 4.1.2 Online Operations Function Name Switch Operation Function Description Offline {S1} LED light ON: Online; LED li

Strona 61 - 6.1 Summary

Tally Dascom 2610 20 4.1.3 Offline Operations Function Name Switch Operation  Function Description. Online {S1}  LED light ON: Online;

Strona 62 - 6.2 IP Configuration

Tally Dascom 2610 21 Detailed descriptions of the above functions: ◆ Speed If LQ font is currently set in the configuration, lighting up of the【Sp

Strona 63

Tally Dascom 2610 22 4.1.4 Power-On Operations Function Name Switch Operation Function Description Technical Setup [S1]  Start Technical Set

Strona 64 - 6.3 WebPanel

Tally Dascom 2610 23 4.2 Operation of the LCD Panel ◆ The Online mode is the printer’s normal operating mode. Data from your computer can be

Strona 65

Tally Dascom 2610 24 4.2.2 Online mode After switching on, the printer is automatically set to online mode. Only in this mode can it receive da

Strona 66

Tally Dascom 2610 25 4.2.4 Setup mode In this mode, the following settings are available: Setup key: Sets the printer to setup mode, in whi

Strona 67

Tally Dascom 2610 26 5 Setting parameters for the printer (Programming via the control panel) Apart from being able to control your printer

Strona 68

Tally Dascom 2610 III Consignes importantes de sécurité (French) Lire attentivement les instructions suivantes avant de mettre l’imprimante en serv

Strona 69

Tally Dascom 2610 27 increment or decrement the TOF value. After adjustment, press Key 1 (Set) to save the change. Set the Tear position in

Strona 70

Tally Dascom 2610 28 5.1.3 Settings within Menu Below example demonstrates how to select an Emulation within the Menu. 1) First load fanfold

Strona 71

Tally Dascom 2610 29 5.2 Setting the parameters through the LCD Panel This chapter describes the handling of the operator’s panel with optional

Strona 72

Tally Dascom 2610 30 5.2.2 Menu configurations Every printer is shipped with factory default settings. Basic settings such as emulation, char

Strona 73

Tally Dascom 2610 31 Menu Printout

Strona 74

Tally Dascom 2610 32 5.2.3 Menu handling You can navigate in the current menu using the four function and selection keys arranged below the L

Strona 75

Tally Dascom 2610 33 5.2.4 Selecting the LC display language This section describes how to make settings in the menu, using the selection of

Strona 76

Tally Dascom 2610 34 5.3 Menu structure The menu structure of your printer may be slightly different from the example shown here, depending o

Strona 77

Tally Dascom 2610 35 5.4 Full list parameters setting In order to meet individual requirements of printer functionality, users may modify

Strona 78

Tally Dascom 2610 36 Prestige NLQ Prestige LQ Script NLQ Script LQ OCR-B NLQ OCR-B LQ OCR-A NLQ OCR-A LQ Orator NLQ Courier I NLQ Courier I LQ Or

Strona 79

Tally Dascom 2610 IV Indicazioni di sicurezza importanti (Italian) Prima di mettere in funzione la stampante, leggere attentamente le seguenti indi

Strona 80

Tally Dascom 2610 37 Format 8Bit No 1Stop 8Bit No 2Stop 8Bit Even 1Stop 8Bit Odd 1Stop 8Bit Mark 1Stop 8Bit Spc 1Stop 7Bit No 2Stop

Strona 81

Tally Dascom 2610 38 ETH-INT IP-Addr Octets 1-4 0 to 255 Input of the IP address of the printer This menu level offers the possibility to set the

Strona 82

Tally Dascom 2610 39 Coax/Twinax Table 437 New-437 Table 737 775 Baltic Table 850 New-Dig 850 Table 851 Table 852 Table 857 Table 858 Table

Strona 83

Tally Dascom 2610 40 Formlen Lines =6 – 132 Default 6LPI = 66 Single:3—22 inches TrFront、TrRear 、 PullTr:1—22 inches Sets the form length via line

Strona 84

Tally Dascom 2610 41 Width Width=13.6Inch Width=8Inch Width=13.2Inch Selects the line length in inches. With the setting of 8 Inch, the print

Strona 85

Tally Dascom 2610 42 5.4.2 Advanced Menu Advanced Menu Valid Settings Function ASCII80 8 inch wide print of test pattern To check operational r

Strona 86

Tally Dascom 2610 43 menu item “Paphand” (Paper Handling). This setting tells the printer logic the width of the installed paper and is valid for a

Strona 87

Tally Dascom 2610 44 Sound Sound=On Sound=Off When Sound=On, a beep is generated every second to notify that paper is empty. Pap.back Pap.back

Strona 88

Tally Dascom 2610 45 a width of 13 mm or more as the right-hand paper edge. If the sensor does not detect any black area, the maximum possible prin

Strona 89

Tally Dascom 2610 46 5.5 Display messages If the printer detects an internal fault or user error or if it expects you to do something, a me

Strona 90 - 7 Addendum

Tally Dascom 2610 V Instrucciones de seguridad importantes (Spanish) Lea las siguientes instrucciones con esmero antes de poner la impresora en ser

Strona 91

Tally Dascom 2610 47 5.5.2 Messages LCD Panel LCD Messages Meaning Eject error The printer cannot eject the paper/advance it to park positio

Strona 92

Tally Dascom 2610 48 6 Web Panel and Internal Ethernet Interface 6.1 Summary 6.1.1 Introduction It is assumed you have the following:

Strona 93

Tally Dascom 2610 49 6.2 IP Configuration 6.2.1 Network IP Configuration The network interface of the printer requires an IP address.

Strona 94

Tally Dascom 2610 50 2. Static assignment using the operator panel: ◆ Press < Setup >, then < Menu >. ◆ Press < Next > until th

Strona 95

Tally Dascom 2610 51 6.3 WebPanel 6.3.1 Introduction WebPanel is an intuitive browser interface that allows you to remotely manage your

Strona 96

Tally Dascom 2610 52 6.3.3 Access to WebPanel & Control Tool 6.3.3.1 Access to WebPanel Once an IP address has been set up, you can access W

Strona 97

Tally Dascom 2610 53 6.3.3.2 Access to Config Tool The software interface for is shown as below. Click “Connect” to select the related inter

Strona 98

Tally Dascom 2610 54 6.3.5 Printer Configuration Selecting this option allows you to configure specific parameters in the printer. When one o

Strona 99

Tally Dascom 2610 55 Example 1 Changing the dropdown menu option. In this example, we are modifying the selected font to a different font. Select “

Strona 100

Tally Dascom 2610 56 Example 2 Changing an entered value menu option. In this example, we are modifying the selected form length to a different for

Strona 101

Tally Dascom 2610 VI Правила по технике безопасности. (Russian) Прочитайте, пожалуйста, инструкцию по технике безопасности перед включением в работ

Strona 102

Tally Dascom 2610 57 6.3.6 Printer Actions Selecting the Printer Actions link will produce a page with a list of actions that can be performe

Strona 103

Tally Dascom 2610 58 6.3.7 Load Configuration Loads the settings stored in a menu into the printer as the current settings. When the Load Con

Strona 104

Tally Dascom 2610 59 6.3.8 Save Configuration You can save selected printer settings in up to 5 independent menus. When the Save Configuratio

Strona 105

Tally Dascom 2610 60 6.3.10 Send Configuration to Printer Selecting this option will upload a Configuration File of another printer (see “Ret

Strona 106

Tally Dascom 2610 61 Use the “Browse” button to find the file to upload. Once the file is selected, click on the “Send” button. It is important to

Strona 107

Tally Dascom 2610 62 6.3.11 Report Selecting the report link will open up a separate browser window and a report of the printer settings will

Strona 108

Tally Dascom 2610 63 After following the directions on this page, select the “Continue“ link and the following page is displayed: Using the “Br

Strona 109

Tally Dascom 2610 64 If the process is successful, the printer will reboot and the following page will be displayed: Since the printer will reboo

Strona 110

Tally Dascom 2610 65 6.3.15 TallyCom Status Selecting this link will replace the information in the Printer Status area with networking infor

Strona 111

Tally Dascom 2610 66 6.3.16 Advanced Configuration The Advanced Configuration page allows the user to set up and modify network connectivity

Strona 112

Tally Dascom 2610 VII Instruções Importantes sobre Segurança (Portuguese) Leia as instruções de segurança antes de usar a impressora.  Consulte

Strona 113 - Direction Printer–PC

Tally Dascom 2610 67 6.3.17 General The General page sets up the timers and the labels for name, contact and location of the printer. Th

Strona 114

Tally Dascom 2610 68 6.3.18 TCP/IP The TCP/IP Page allows the user to modify the existing TCP/IP information for the printer. After changing

Strona 115

Tally Dascom 2610 69 6.3.19 SNMP The SNMP page allows the user to set the Community Name and the Access. The page looks like this:

Strona 116 - Protocols

Tally Dascom 2610 70 6.3.20 Password The Password page allows the user to set a password which would limit access to certain configuration

Strona 117

Tally Dascom 2610 71 6.3.23 Email Notification With the email notification link the user will be able to set up and receive email notices for

Strona 118 - 8 Options and accessories

Tally Dascom 2610 72 The “Configure” link at the end of each line of notification options allows the user to set up the message information for t

Strona 119 - 8.3 Accessories

Tally Dascom 2610 73 6.3.24 Logical Printers The logical printers page will add text or commands to the beginning and ending of print jobs. T

Strona 120 - 9 General Specifications

Tally Dascom 2610 74 When selecting one of the logical printers under the Description column, the following page is displayed: In this example i

Strona 121

Tally Dascom 2610 75 6.3.26 Logout of TallyCom The Logout link disconnects the browser session from the printer. Clicking on the “Home” link ree

Strona 122

Tally Dascom 2610 76 6.3.28 Virtual Control Panel The Virtual Control Panel link is in the Printer Status area of the web page. This control pan

Strona 123

Tally Dascom 2610 VIII Önemli Güv enlik Talimatları (Turkish) Lütfen, yazıcıyı işletime geçirmeden önce bu güv enlik talimatlarını bütünüyle dikk

Strona 124

Tally Dascom 2610 77 7 Addendum 7.1 Character Set standard character set 1 standard character set 2

Strona 125

Tally Dascom 2610 78 IBM character set 1 IBM character set 2

Strona 126 - versions

Tally Dascom 2610 79 OCR-A character set 1 OCR-A character set 2

Strona 127 - 9.3.3 Paper Weights

Tally Dascom 2610 80 OCR-B character set 1 OCR-B character set 2

Strona 128 - 10 Maintenance

Tally Dascom 2610 81 International Character Set Commands Country Basic Command USA <ESC>“R”CHR$(0) FRANCE <ESC>“R”CHR$(1) GERMANY <ESC>“R”CHR$(2)

Strona 129 - 10.2 Troubleshooting

Tally Dascom 2610 82 7.2 Control Codes Summary The following table shows sequences marked by a √ if they are available in the various emul

Strona 130

Tally Dascom 2610 83 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ * * * * <ESC>(. Character set ISO 8859-9 √ * * * *

Strona 131

Tally Dascom 2610 84 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ √ √ <ESC>*<4><n1> <n2> Set gra

Strona 132 - FCC STATEMENT

Tally Dascom 2610 85 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ * * * * <ESC>[?7l Line overrun = Truncating data o

Strona 133 - DASCOM REPRESENTATIVES

Tally Dascom 2610 86 MTPL IBM XL24 IBM AGM Epson LQ-2550 Epson LQ-2170 Code Function √ * * * * <ESC>[16m Font 6 Default: Script LQ √ * *

Powiązane modele: 2610 User Guide

Komentarze do niniejszej Instrukcji

Brak uwag